Chlorophyll content and fluorescence responses cannot be used to gauge reliably phytoplankton biomass, nutrient

Mikaela Kruskopf1, Kevin J Flynn

  • 1Institute of Environmental Sustainability, Wallace Building, University of Wales Swansea, Swansea SA2 8PP, UK.

The New Phytologist
|January 18, 2006
PubMed

Related Concept Videos

Photoreceptors and Plant Responses to Light02:00

Photoreceptors and Plant Responses to Light

Light plays a significant role in regulating the growth and development of plants. In addition to providing energy for photosynthesis, light provides other important cues to regulate a range of developmental and physiological responses in plants.
Microbial Growth Measurement: Indirect Methods01:27

Microbial Growth Measurement: Indirect Methods

Estimating microbial growth is essential for understanding population dynamics and environmental adaptations. Indirect methods provide valuable insights by measuring parameters such as turbidity, metabolic activity, and biomass, enabling efficient and reproducible assessments.During exponential growth, microbial cells scatter light proportionally to their biomass, a principle used in turbidity measurements. About one million cells per milliliter produce detectable scattering, which a...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...