Static and fatigue compression test for particulate filler composite resin with fiber-reinforced composite
Sufyan Garoushi1, Lippo V J Lassila, Arzu Tezvergil
1Department of Prosthetic Dentistry and Biomaterials Science, Institute of Dentistry, University of Turku, Lemminkäisenkatu 2, FI-20520 Turku, Finland. sufgar@utu.fi
Objectives:
The aim of this study was to determine static load-bearing capacity and compressive fatigue limits (CFL) of laboratory particulate filler composite resin (PFC) with three different types of fiber-reinforced composite (FRC) substructures.
Methods:
A total of 420 test specimens were prepared having 1.0mm of FRC layer as substructure (short random, continuous unidirectional and bidirectional fiber orientations), and a 2.0-mm thick surface layer of PFC. Control specimens were prepared from plain FRC or PFC. The specimens (n=15) were either dry stored or water stored (37 degrees C for 2 weeks) before they were loaded with a steel ball (Ø 3.0mm) under static load until fracture and cyclic load with maximum controlled regimen following a staircase approach with maximum 10(3) cycles. The decrease in CFL compared to static load was calculated and data were analyzed using ANOVA and Weibull statistics.
Results:
The highest static loads were registered for plain FRC specimens [short random 1842 N(205), continuous bidirectional 2258 N(233) and unidirectional fiber orientation 538 N(254)]. The specimens with FRC substructure and PFC coverage gave load values of 1517 N(249), 1670 N(241) and 677 N(240), respectively. The specimens made of PFC only, failed with 1047 N(230) load. The CFL for 10(3) cycles ranged between 19 and 39% of the static load values. ANOVA revealed that all factors significantly affected the load bearing capacity (p<0.001).
Significance:
The results suggested that the material combination of continuous bidirectional or random FRC and PFC, gave higher CFL and static load-bearing capacity than that obtained with plain particulate filler composite resin.
More Related Videos
Related Concept Videos
Fatigue Strength of Concrete
Fiber Reinforced Concrete
Fatigue
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...