Related Experiment Video
Updated: Aug 1, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Computer-designed inlays after 5 years in situ: clinical performance and scanning electron microscopic evaluation
Abstract:
Eight mesio-occlusodistal adhesive inlays, fabricated from ceramic blocks using a computer-aided design/machining method, were reexamined after 5 years of clinical service. The inlays wre evaluated according to modified US Public Health Service criteria. The results indicated excellent clinical performance, with eight Alfa ratings for wear, recurrent caries, and color match, and five Alfa and three Bravo for marginal discoloration and marginal integrity. Under scanning electron microscope, 81.0% of the tooth-cement interfaces and 84.1% of the cement-inlay interfaces were rated continuous at the occlusal margin. Axially, 73.6% of the tooth-cement interfaces and 87.0% of the cement-inlay interfaces were rated continuous. Although this long-term investigation revealed good clinical performance of the inlays, improvements in the ceramic structure and its properties, the cavosurface design, and the luting composite resin were recently introduced to further optimize quality.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:10Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025