Mersilene mesh versus sclera in wrapping hydroxyapatite orbital implants
Abolfazl Kassaee1, Mohsen Bahmani Kashkouli, Mohammadreza Panjtanpanah
1Oculoplastic Service, Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Iran.
Ophthalmic Plastic and Reconstructive Surgery
|January 19, 2006
Summary
Mersilene mesh and sclera are safe wrapping materials for hydroxyapatite orbital implants after enucleation. Mersilene mesh offers advantages like availability and low cost, with no reported implant exposure in this study.
Area of Science:
- Ophthalmology
- Biomaterials Science
- Surgical Innovation
Background:
- Hydroxyapatite implants are commonly used after orbital exenteration.
- Biocompatible wrapping materials are essential for successful implant integration and patient comfort.
- Comparing different wrapping materials like Mersilene mesh and sclera is crucial for optimizing outcomes.
Purpose of the Study:
- To compare the efficacy and safety of Mersilene mesh versus sclera as wrapping materials for hydroxyapatite orbital implants in primary enucleation procedures.
- To evaluate postoperative complications and implant stability associated with each wrapping material.
Main Methods:
- A prospective, randomized, comparative case series involving 60 patients undergoing primary enucleation.
- Patients were allocated to receive either Mersilene mesh-wrapped hydroxyapatite (MHA) or sclera-wrapped hydroxyapatite (SHA) implants.
- Socket examinations were conducted at regular intervals post-surgery (1 week, 1 month, and every 3 months).
Main Results:
- No significant difference in mean patient age or primary cause for enucleation (trauma) between MHA and SHA groups.
- MHA implants had a significantly longer mean follow-up duration (11.40 months) compared to SHA (9.40 months).
- No implant exposure was observed in the MHA group, while one SHA patient experienced minor exposure treated conservatively. No significant soft tissue complications occurred in either group.
Conclusions:
- Both Mersilene mesh and sclera are suitable and safe wrapping materials for hydroxyapatite orbital implants.
- Mersilene mesh presents advantages including no disease transmission, cost-effectiveness, and ready availability.
- The study supports the use of Mersilene mesh as a viable alternative for wrapping orbital implants.