Related Experiment Video
Updated: Aug 13, 2026

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Comparison of patient doses in 256-slice CT and 16-slice CT scanners
1Department of Medical Physics, National Institute of Radiological Sciences, Chiba 263-8555, Japan.
Abstract:
The 256-slice CT-scanner has been developed at the National Institute of Radiological Sciences. Nominal beam width was 128 mm in the longitudinal direction. When scanning continuously at the same position to obtain four-dimensional (4D) images, the effective dose is increased in proportion to the scan time. Our purpose in this work was to measure the dose for the 256-slice CT, to compare it with that of the 16-slice CT-scanner, and to make a preliminary assessment of dose for dynamic 3D imaging (volumetric cine imaging). Our group reported previously that the phantom length and integration range for dosimetry needed to be at least 300 mm to represent more than 90% of the line integral dose with the beam width between 20 mm and 138 mm. In order to obtain good estimates of the dose, we measured the line-integral dose over a 300 mm range in PMMA (polymethylmethacrylate) phantoms of 160 mm or 320 mm diameter and 300 mm length. Doses for both CT systems were compared for a clinical protocol. The results showed that the 256-slice CT generates a smaller dose than the 16-slice CT in all examinations. For volumetric cine imaging, we found an acceptable scan time would be 6 s to 11 s, depending on examinations, if dose must be limited to the same values as routine examinations with a conventional multidetector CT. Finally, we discussed the studies necessary to make full use of volumetric cine imaging.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
