Related Experiment Video
Updated: Aug 13, 2026

Modifying Levels of Maternal Dietary Folic Acid or Choline to Study the Impact of Deficiencies on Offspring Health Outcomes
Published on: June 28, 2024
Correction for errors in measuring adherence to prenatal multivitamin/mineral supplement use among low-income women
Sunitha Jasti1, Anna Maria Siega-Riz, Mary E Cogswell
1Department of Family, Nutrition and Exercise Sciences, Queens College of City University of New York, Flushing, NY 11367, USA. sunitha_jasti@qc.edu
Adherence to prenatal multivitamin/mineral supplement use is often measured by self-reports or pill counts. Although both measures were shown to overestimate adherence, measurement error is rarely considered. In this study, we examined measurement error in adherence to prenatal supplement use among pregnant women and demonstrated a calibration method to adjust for error. In a validation subsample (n=51) from a larger clinical study of supplementation, adherence was assessed by self-reports, pill counts, and a Medication Event Monitoring System (MEMS) bottle cap that recorded the date and time of each opening of the pill bottle. Mean adherence in the validation sample as measured by the MEMS (the gold standard) was 68%; thus, adherence measured by self-report (77%) and pill count (84%) reflected overestimation. The Pearson correlation coefficients of self-reports and pill counts to MEMS were 0.35 and 0.62, respectively. When adherence was defined as taking >or=75% of the pills prescribed, sensitivity and specificity were greater for pill counts (93 and 52%, respectively) than for self-reports (88 and 44%). The regression coefficient for pill count adherence from a linear regression on MEMS adherence was applied to pill counts from a larger sample (n=244). The adjustment significantly lowered the estimate of adherence from 74 to 64% (P<0.001) in this larger sample. In conclusion, our data show that both self-reports and pill counts overestimate adherence and that linear regression in comparison to an external standard such as MEMS can be used to correct for measurement error in adherence.
Adherence to prenatal multivitamin/mineral supplement use is often measured by self-reports or pill counts. Although both measures were shown to overestimate adherence, measurement error is rarely considered. In this study, we examined measurement error in adherence to prenatal supplement use among pregnant women and demonstrated a calibration method to adjust for error. In a validation subsample (n=51) from a larger clinical study of supplementation, adherence was assessed by self-reports, pill counts, and a Medication Event Monitoring System (MEMS) bottle cap that recorded the date and time of each opening of the pill bottle. Mean adherence in the validation sample as measured by the MEMS (the gold standard) was 68%; thus, adherence measured by self-report (77%) and pill count (84%) reflected overestimation. The Pearson correlation coefficients of self-reports and pill counts to MEMS were 0.35 and 0.62, respectively. When adherence was defined as taking >or=75% of the pills prescribed, sensitivity and specificity were greater for pill counts (93 and 52%, respectively) than for self-reports (88 and 44%). The regression coefficient for pill count adherence from a linear regression on MEMS adherence was applied to pill counts from a larger sample (n=244). The adjustment significantly lowered the estimate of adherence from 74 to 64% (P<0.001) in this larger sample. In conclusion, our data show that both self-reports and pill counts overestimate adherence and that linear regression in comparison to an external standard such as MEMS can be used to correct for measurement error in adherence.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Regression Toward the Mean
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...