Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Shear bond strength with increasing light-guide distance from dentin.

Xiaoming Xu1, Dant A Sandras, John O Burgess

  • 1Department of Operative Dentistry and Biomaterials, Louisiana State University Health Sciences Center School of Dentistry, New Orleans 70119, USA. xxu@lsuhsc.edu

Journal of Esthetic and Restorative Dentistry : Official Publication of the American Academy of Esthetic Dentistry ... [Et Al.]
|January 24, 2006
PubMed
Summary

For deep Class II composite restorations, increasing curing time to 40-60 seconds compensates for reduced light intensity at greater distances. This ensures optimal resin composite bond strength and polymerization, crucial for durable dental work.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Re: Thomas Dreyer, Simone Brandt, Knud Fabrin, et al. Use of the Xpert Bladder Cancer Monitor Urinary Biomarker Test for Guiding Cystoscopy in High-grade Non-muscle-invasive Bladder Cancer: Results from the Randomized Controlled DaBlaCa-15 Trial. Eur Urol. 2025;88:23-30.

European urology·2025
Same author

Intrawound vancomycin powder reduces lumbar surgical site infection in spine surgery.

International journal of surgery (London, England)·2025
Same author

Comment on "Surgical resection for small (≤2 cm) gastric gastrointestinal stromal tumor".

European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology·2025
Same author

Effects of Intra-patient Lung Volume Variability on CT-Based Emphysema Quantification: A Virtual Imaging Study.

Academic radiology·2025
Same author

Is the risk of new Barrett's esophagus after sleeve gastrectomy overestimated?

Gastrointestinal endoscopy·2025
Same author

Ectoparasites enhance survival by suppressing host exploration and limiting dispersal.

Nature communications·2025

Area of Science:

  • Dental Materials Science
  • Polymer Chemistry
  • Restorative Dentistry

Background:

  • Class II composite restorations require adequate curing of adhesives in deep preparations, often 2-8 mm from the light source.
  • Typical 10-second curing times may be insufficient for proper polymerization at these distances.

Purpose of the Study:

  • To evaluate dentin bond strengths of resin composite with varying curing light guide distances.
  • To investigate the relationship between radiant exposure, degree of conversion, and shear bond strength.

Main Methods:

  • Single Bond adhesive was applied to dentin, followed by curing with a quartz-tungsten-halogen light at distances of 0-6.9 mm for 20, 40, or 60 seconds.
  • Z100 resin composite was polymerized, and shear bond strengths were tested after 24-hour water storage.

Related Experiment Videos

  • Irradiance, degree of conversion, and bond strength data were analyzed.
  • Main Results:

    • Dentin shear bond strengths significantly decreased as curing distance increased.
    • Increasing curing time to 40 or 60 seconds significantly improved bond strengths.
    • A linear correlation was found between shear bond strength, degree of conversion, and the logarithm of radiant exposure.

    Conclusions:

    • Extended curing times (40-60 seconds) can effectively compensate for reduced irradiance caused by increased distance in deep cavity preparations.
    • Optimal polymerization and bond strength in deep Class II composite restorations are achieved by increasing curing time with quartz-tungsten-halogen lights.