Abstract:
2-DE is a powerful separation method for complex protein mixtures. However, large intergel variations in spot intensity limit its use for quantitative proteomics studies. To address this issue, we developed a fluorescent internal protein standard for use in 2-DE analysis. Protein samples are spiked with an Alexa-labeled internal standard (ALIS) prior to separation with 2-DE. Due to the high extinction coefficient of the Alexa-fluor, incorporation of 0.1% of total protein is sufficient to allow visualization of the internal standard yet low enough to avoid interference in subsequent quantification and identification steps. Following 2-DE, total proteins are visualized with fluorescent postelectrophoretic stains spectrally separated from ALIS. Four protein stains, Deep Purple, Sulforhodamine G, ruthenium II-tris(bathophenanthroline disulfonate) (RuTBS), and SYPRO Ruby, including improved purification and staining protocols for RuTBS and ten-fold dilutions of SYPRO Ruby were evaluated. All staining protocols were compatible with the ALIS method and had similar LODs (1-4 ng) and dynamic ranges (10(3)). ALIS is a powerful normalization method for quantitative 2-DE which avoids potential problems associated with dual spot migration patterns observed in the DIGE method. Furthermore, ALIS provides significantly improved normality in the distribution of spot abundance-variance compared to normalization through division by the total spot volume.
More Related Videos
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.