Related Experiment Video
Updated: Aug 13, 2026

Surgical Swine Model of Chronic Cardiac Ischemia Treated by Off-Pump Coronary Artery Bypass Graft Surgery
Published on: March 27, 2018
Low-prime system minimizes transfusions and hemodilution in coronary bypass
Sven Beholz1, Liling Zheng, Martin Rusche
1Department of Cardiovascular Surgery, Charité-University Medicine Berlin, Berlin, Germany. sven.beholz@charite.de
Abstract:
Standard heart-lung machines lead to substantial hemodilution with associated impaired organ function and increased need for blood transfusions. The aim of this study was to evaluate the effect of the new PRECiSe low prime volume system on perioperative myocardial damage, hemodilution, and transfusions. In a case-matched prospective study, 40 patients undergoing coronary artery bypass surgery using PRECiSe were compared with 40 patients on a standard heart-lung machine. In the PRECiSe group, the prime volume was significantly reduced, resulting in less hemodilution and transfusion requirements during and after extracorporeal circulation: only 10% of patients needed transfusions vs. 35% in the control group, with an average transfusion need of 0.16 vs. 1.25 units. There were no significant differences in perioperative cardiac-specific enzymes. The PRECiSe system was considered safe and effective for coronary artery bypass surgery.