Related Experiment Video
Updated: Aug 13, 2026

Standard Test Method ASTM D 7998-19 for the Cohesive Strength Development of Wood Adhesives
Published on: May 17, 2020
Tensile bond strength of self-etching adhesive systems to primary dentin
Carolina Paes Torres1, Juliane Cristine Ciccone, Renata Pereira Ramos
1Faculdade de Odontologia de Ribeirão Preto/USP. Departamento de Clinica Infantil, Odontologia Preventiva e Social, Av. do Café, s/n, Monte Alegre. CEP: 14040-904 Ribeirão Preto-SP Brasil. caroltorres@forp.usp.br
Purpose:
To assess in vitro the bond strength of three self-etching adhesive systems to primary teeth dentin.
Methods:
Fifteen crowns of primary molars were sectioned mesiodistally and embedded in acrylic resin (n=30). Dentin was exposed and the specimens were randomly assigned in groups (n=10): (1) Clearfil SE Bond; (2) Prime & Bond NT/NRC; and (3) One Up Bond F. A 3 mm-diameter dentin bonding site was demarcated, the adhesive systems were applied and resin composite cones were bonded. After 24 hours in distilled water, tensile bond strength was tested to failure (0.5 mm/minute). Data were submitted to statistical analysis using one-way ANOVA and Scheffé test.
Results:
Means were (MPa): (1) 16.60 (+/- 4.10); (2) 8.48 (+/- 4.51); and (3) 6.75 (+/- 1.26). CSE Bond yielded significantly higher bond strengths (P < 0.05). Prime & Bond NT/NRC and One Up Bond F means were markedly low and no statistically significant difference was observed between them.