Related Experiment Video
Updated: Aug 13, 2026

Watershed Planning within a Quantitative Scenario Analysis Framework
Published on: July 24, 2016
Phase-in of nonpoint sources in a transferable discharge permit system for water quality management: setting permit
1Division of Economics, Gävle University, Sweden. dce@hig.se
Abstract:
The composite market design is a proposal for a transferable discharge permit system that specifically includes agricultural non-point-source dischargers and addresses both property rights and transaction cost problems. The first step to implementation of a composite market scheme is the estimation of a supply curve for abatement measures in the catchment area. Estimation is performed by combining costs with modeled loss reductions from selected best management practices and then using this information to estimate the supply curve for abatement, which in turn can then be used to set permit prices. The Rönneå catchment in southern Sweden is used as a pilot study area for making this type of estimate. Costs for existing measures that reduce nutrient losses from farmland (catch crops and spring planting) are based on existing programs financed by the Swedish Agricultural Board. A set of supply curves is calculated for these measures using retention estimates for seven subcatchments and three soil types in the area. Although existing information is sufficient to calculate partial supply curves and may be used to set permit prices, additional measures should be included as well as an increased number of variables for differentiating site specific reduction costs.
More Related Videos
06:26Capturing Flow-weighted Water and Suspended Particulates from Agricultural Canals During Drainage Events
Published on: November 7, 2017
08:09Wastewater Irrigation Impacts on Soil Hydraulic Conductivity: Coupled Field Sampling and Laboratory Determination of Saturated Hydraulic Conductivity
Published on: August 19, 2018
Related Concept Videos
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
The Phase Rule
Electrochemical Systems
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are known. The...
Biological Treatment of Effluent and Waste Water