H-point standard addition method--first derivative spectrophotometry for simultaneous determination of palladium and
1Department of Chemistry, Faculty of Basic Sciences, University of Mohaghegh Ardebili, Ardebil 179, Iran. habibollah-eskandari@uma.irost.net
Abstract:
H-point standard addition method (HPSAM) has been applied for simultaneous determination of palladium and cobalt in trace levels, using disodium 1-nitroso-2-naphthol-3, 6-disulphonate (nitroso-R salt) as a selective chromogenic reagent. Palladium and cobalt in the neutral pHs form red color complexes with nitroso-R in aqueous solutions and making spectrophotometric monitoring possible. Simultaneous determination of palladium and cobalt were performed by HPSAM--first derivative spectrophotometry. First derivative signals at the two pairs of wavelengths, 523 and 589 nm or 513 and 554 nm were monitored with the addition of standard solutions of palladium or cobalt, respectively. The method is able to accurately determine palladium/cobalt ratio 1:10 to 15:1 (wt/wt). Accuracy and reproducibility of the determination method on the various amounts of palladium and cobalt known were evaluated in their binary mixtures. To investigate selectivity of the method and to ensure that no serious interferences were observed the effects of diverse ions on the determination of palladium and cobalt were also studied. The recommended procedure was successfully applied to real and synthetic cobalt or palladium alloys, B-complex ampoules, a palladium-charcoal mixture and real water matrices.
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...


