Related Experiment Video
Updated: Jan 8, 2026

Environmental Modulations of the Number of Midbrain Dopamine Neurons in Adult Mice
Published on: January 20, 2015
Fundal dysaccommodation in functional dyspepsia: head-to-head comparison between the barostat and three-dimensional
1Gastrointestinal Research Unit, Department of Gastroenterology and Hepatology, University Medical Center, PO Box 85500, 3508 GA Utrecht, The Netherlands.
Background:
Recently, non-invasive techniques such as 3 dimensional ultrasonography (3DUS) have been developed to assess gastric wall characteristics and to investigate their relationship with upper gastrointestinal sensations. To date, no head-to-head comparison has been carried out between the barostat and the 3DUS technique.
Aim:
To compare barostat and 3DUS and to investigate the relationship between gastric volumes and sensations in patients with functional dyspepsia and in healthy subjects.
Patients And Methods:
Gastric accommodation was studied in 15 patients with functional dyspepsia and in 15 healthy subjects after ingestion of a liquid nutrient (300 kcal) using barostat and 3DUS in random order for 60 min. Proximal gastric relaxation was measured using barostat and gastric volume using 3DUS. Change in gastric volume, acquired by 3DUS, was expressed as total gastric volume/proximal volume ratio (TGV/PV) and compared with changes in barostat volume (fundal accommodation).
Results:
Patients with functional dyspepsia showed a smaller change in proximal gastric volume than healthy subjects using barostat (mean (SD) 82 (61) v 205 (79) ml, p<0.01) and 3DUS (118 (41) v 199 (39) ml, p<0.01). Dysaccommodation of the proximal stomach was observed in 7 of 15 (46%) patients using the barostat technique. 10 of 15 (67%) patients were found to have an abnormal change in proximal gastric volume using TGV/PV ratio. At 5 min postprandially, fullness was related to the change in distal gastric volume (r = 0.51, p = 0.006) in the 3DUS study, whereas no relationship was observed in the barostat study.
Conclusion:
3DUS is a feasible non-invasive technique to measure gastric volumes and shows a distinct overlap with barostat data in healthy subjects and patients with functional dyspepsia. Fullness relates to distal gastric volumes when assessed by non-invasive 3DUS.
Related Concept Videos
09:21Phenotypic Profiling of Human Stem Cell-Derived Midbrain Dopaminergic Neurons
10:54Reliable Identification of Living Dopaminergic Neurons in Midbrain Cultures Using RNA Sequencing and TH-promoter-driven eGFP Expression
08:45Isolation, Culture and Long-Term Maintenance of Primary Mesencephalic Dopaminergic Neurons From Embryonic Rodent Brains
09:35Environmental Modulations of the Number of Midbrain Dopamine Neurons in Adult Mice
11:58Primary Culture of Mouse Dopaminergic Neurons
09:54Comprehensive Profiling of Dopamine Regulation in Substantia Nigra and Ventral Tegmental Area