Comparison of DDD and 'VVI-R like' pacing during moderate exercise: echo-Doppler study
1Service de Cardiologie, Hôpital Jean Rostand, Ivry Sur Seine, France.
Dual chamber pacing (DDD) offers superior hemodynamic performance compared to ventricular pacing (VVI-R) during exercise. DDD pacing resulted in significantly larger stroke volume and cardiac output, demonstrating its advantage in maintaining circulatory function.
Area of Science:
- Cardiology
- Biomedical Engineering
- Physiology
Background:
- Dual chamber pacing (DDD) and ventricular pacing (VVI-R) are common modes for cardiac rhythm management.
- Understanding their hemodynamic effects during exercise is crucial for optimizing patient care.
Purpose of the Study:
- To compare the non-invasive hemodynamic effects of DDD and VVI-R pacing modes at rest and during moderate exercise using echocardiography Doppler.
Main Methods:
- Twelve patients with dual chamber pacemakers underwent two exercise tests: one in DDD mode and another in a VVI-R like (VVT) mode.
- Ventricular pacing rate was matched to the DDD mode's heart rate profile during the VVI-R test via external chest wall stimulation.
- Echocardiography Doppler was used to record and analyze aortic blood flow velocity spectra, calculating parameters like stroke volume and cardiac output.
Main Results:
- At rest, several hemodynamic parameters differed between DDD and VVI-R modes, including ejection time, flow velocity integral, flow acceleration, and stroke volume.
- During exercise, most parameters differed, with DDD mode showing significantly larger stroke volume (81.9 vs 70.9 ml) and cardiac output (9.24 vs 8.01 L/min) compared to VVI-R mode (P < 0.001 for both).
Conclusions:
- DDD pacing demonstrates superior hemodynamic efficiency over VVI-R pacing during moderate exercise in patients with dual chamber pacemakers.
- The findings suggest that DDD pacing better supports circulatory function during physical activity compared to VVI-R pacing.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...