Concealed conduction in nodal dual pathways: depressed conduction, prolonged refractoriness, or reset excitability
Bochun Xu1, Jacques Billette, Michel Lavallée
1Département de Physiologie, Faculté de Médecine, Université de Montréal, Montréal, Quebec, Canada.
Background:
Concealed conduction is recognized as a major determinant of atrioventricular (AV) nodal filtering properties, but little is known about the underlying mechanisms.
Objectives:
The purpose of this study was to consistently elicit concealed conduction through the AV node and to determine the involvement of slow and fast pathways in resultant changes in nodal function.
Methods:
The concealment zone (nodal effective refractory period minus nodal functional refractory period of atrium) was determined in six rabbit heart preparations with and without a conditioning cycle (10 ms longer than nodal effective refractory period). Nodal function curves were constructed for concealed cycle lengths selected within the concealment zone. Experiments were repeated after slow pathway ablation.
Results:
When assessed with a blocked beat alone, a narrow concealment zone (22 +/- 12 ms, n = 3) was observed in 50% of the preparations. In contrast, when assessed with a blocked beat preceded by a conducted conditioning beat, a wider concealment zone (77 +/- 47 ms, n = 6, P <.03) was observed in all preparations. Increases in the concealed cycle length resulted in graded increases in the nodal effective refractory period and nodal functional refractory period and graded rightward shifts of the recovery curve as a whole, consistent with resetting of the excitability cycle in the slow and fast pathways. These effects were analogous to those expected from a conducted beat. Slow pathway ablation widened the concealment zone but failed to alter fast pathway resetting.
Conclusion:
Our approach reveals a wide concealment zone consistently displayed in all preparations. Concealed conduction acts as a resetting mechanism of the excitability cycle in the slow and fast pathways similar to that expected from a conducted beat.
More Related Videos
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Electrophysiology of Normal Cardiac Rhythm
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Mechanism of Cardiac Arrhythmias