A new approach for evaluating carryover and its influence on quantitation in high-performance liquid chromatography
Wei Zeng1, Donald G Musson, Alison L Fisher
1Department of Drug Metabolism, Merck & Co. Inc., Merck Research Laboratories, West Point, PA 19486-0004, USA. wei_zeng@merck.com
Abstract:
In a high-performance liquid chromatography (HPLC)-based analytical method, carryover denotes one type of systematic error that is derived from a preceding sample and introduced into the next sample. For typical bioanalytical method development, a significant amount of time and resources are spent on reducing carryover for some analytes. In this paper, the statistical characteristics of carryover were analyzed based on the experimental results. The relative carryover (RC), defined as the peak area ratio of a blank sample to the preceding sample, was constant for the analyte and independent of the concentration of the preceding sample. The influence of carryover on the quantitation of the next injected sample or the 'following' sample was proportional to the concentration ratio of two consecutive samples and the relative carryover. Based on these experiments and analyses, the influence of carryover on the quantitation of unknown samples in an HPLC assay can be evaluated by the estimated carryover influence (ECI), which is the product of the relative carryover and the concentration ratio. This new approach provides a quantitative estimation for the influence of carryover on the quantitation of the unknown sample, and removes the limit put on the dynamic range of the assay by the current criterion of carryover. In general, if the relative standard deviation (RSD) of a validated bioanalytical method is less than 10%, the carryover will not have a significant effect on the accuracy of the assay when the estimated carryover influence is less than 5%.
More Related Videos
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry (UPLC-MS)
Published on: March 14, 2013
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation