Surface-activated chemical ionization versus electrospray ionization in the study of selected aluminium(III)/ligand
Rapid Communications in Mass Spectrometry : RCM
|February 1, 2006
Abstract
No abstract available in PubMed .
More Related Videos
07:54Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
10:22In Situ SIMS and IR Spectroscopy of Well-defined Surfaces Prepared by Soft Landing of Mass-selected Ions
Published on: June 16, 2014
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Electrospray Ionization (ESI) Mass Spectrometry
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Extraction: Advanced Methods
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is formed in...
Ion-Exchange Chromatography
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
EDTA: Auxiliary Complexing Reagents
EDTA titrations are usually carried out in highly basic conditions, where the fully deprotonated form of EDTA, Y4−, actively complexes with the free metal ions in the solution. Several metal ions precipitate as hydrous oxide (hydroxides, oxides, or oxyhydroxides) under these conditions, lowering the concentration of free metal ions in the solution. For this reason, auxiliary complexing agents or ligands such as ammonia, tartrate, citrate, or triethanolamine are used in EDTA titrations to...
Determining the pH of Salt Solutions
The pH of a salt solution is determined by its component anions and cations. Salts that contain pH-neutral anions and the hydronium ion-producing cations form a solution with a pH less than 7. For example, in ammonium nitrate (NH4NO3) solution, NO3− ions do not react with water whereas NH4+ ions produce the hydronium ions resulting in the acidic solution. In contrast, salts that contain pH-neutral cations and the hydroxide ion-producing anions form a solution with a pH greater than 7. For...
