Suspected aortic dissection and other aortic disorders: multi-detector row CT in 373 cases in the emergency setting
Robert G Hayter1, James T Rhea, Andrew Small
1Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, 02115, USA. robert_hayter@student.hms.harvard.edu
Insights
Multi-detector row computed tomography (CT) effectively detects acute aortic disorders in emergency settings, demonstrating high accuracy. This study highlights CT
Area of Science:
- Radiology
- Cardiovascular Imaging
- Emergency Medicine
Background:
- Acute aortic disorders, including dissection, intramural hematoma, penetrating ulcers, aneurysms, and rupture, are critical emergencies.
- Early and accurate diagnosis is vital for patient outcomes.
- Multi-detector row computed tomography (CT) has become a primary imaging modality in the emergency evaluation of suspected aortic pathology.
Purpose of the Study:
- To evaluate the diagnostic performance of multi-detector row CT in identifying acute aortic disorders in an emergency setting.
- To determine the sensitivity, specificity, and accuracy of CT in detecting various acute aortic conditions.
Main Methods:
- A retrospective review of 373 emergency evaluations involving patients with suspected aortic dissection or other aortic disorders.
- Patients underwent multi-detector row CT, with diagnoses confirmed by surgical, pathological, or clinical follow-up.
- Performance metrics including sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated.
Main Results:
- Of 373 cases, 18.0% (67 cases) were positive for acute aortic disorders, encompassing dissections, intramural hematomas, ulcers, aneurysms, and ruptures.
- CT demonstrated high diagnostic accuracy with an overall sensitivity of 99% and specificity of 100%.
- Alternative CT findings explained the clinical presentation in 81.8% of negative cases.
Conclusions:
- Multi-detector row CT is a highly accurate tool for the emergency detection of acute aortic disorders.
- The positivity rate for acute aortic disorders in this cohort was 18.0%.
- CT provides comprehensive evaluation, identifying both acute aortic pathology and alternative diagnoses.
Purpose:
To retrospectively review the authors' experience with multi-detector row computed tomography (CT) for detection of aortic dissection in the emergency setting.
Materials And Methods:
The investigation was institutional review board approved, did not require informed patient consent, and was HIPAA compliant. In 373 clinical evaluations in the emergency setting, 365 patients suspected of having aortic dissection and/or other aortic disorders underwent multidetector CT. Criteria for acute aortic disorder were confirmed by using surgical and pathologic diagnoses or findings at clinical follow-up and any subsequent imaging as the reference standard. Positive cases were characterized according to type of disorder interpreted. Resulting sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated by using two-way contingency tables. All cases found to be negative for acute aortic disorders were grouped according to alternative CT findings.
Results:
Sixty-seven (18.0%) of the 373 cases were interpreted as positive for acute aortic disorder. One hundred twelve acute aortic disorders were identified in these 67 cases: 23 acute aortic dissections, 14 acute aortic intramural hematomas, 20 acute penetrating aortic ulcers, 44 new or enlarging aortic aneurysms, and 11 acute aortic ruptures. Three hundred five (81.8%) cases were interpreted as negative for acute aortic disorder. In 48 negative cases, multidetector CT depicted alternative findings that accounted for the clinical presentation. Of these, three included both acute aortic disorders and alternative findings, and 45 included only alternative findings. One (0.3%) case was indeterminate for acute aortic disorder. Overall, 112 findings were interpreted as positive for acute aortic disorder, an alternative finding, or both at CT. No interpretations were false-positive, one was false-negative, 67 were true-positive, and 304 were true-negative. Sensitivity, specificity, PPV, NPV, and accuracy were 99% (67 of 68), 100% (304 of 304), 100% (67 of 67), 99.7% (304 of 305), and 99.5% (371 of 373), respectively.
Conclusion:
The positivity rate for acute aortic dissection or other acute aortic disorder in 373 cases examined at multi-detector row CT was 18.0%.
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Aneurysm IV: Nursing Management