Related Experiment Video
Updated: Aug 11, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
18F-FET PET compared with 18F-FDG PET and CT in patients with head and neck cancer
Dirk Pauleit1, Andre Zimmermann, Gabriele Stoffels
1Institute of Medicine and Brain Imaging Center West, Research Center Jülich, Jülich, Germany. pauleit@web.de
Unlabelled:
Recent studies suggest a somewhat selective uptake of O-(2-[18F]fluoroethyl)-L-tyrosine (FET) in cerebral gliomas and in squamous cell carcinoma (SCC) and a good distinction between tumor and inflammation. The aim of this study was to investigate the diagnostic potential of 18F-FET PET in patients with SCC of the head and neck region by comparing that tracer with 18F-FDG PET and CT.
Methods:
Twenty-one patients with suspected head and neck tumors underwent 18F-FET PET, 18F-FDG PET, and CT within 1 wk before operation. After coregistration, the images were evaluated by 3 independent observers and an ROC analysis was performed, with the histopathologic result used as a reference. Furthermore, the maximum standardized uptake values (SUVs) in the lesions were determined.
Results:
In 18 of 21 patients, histologic examination revealed SCC, and in 2 of these patients, a second SCC tumor was found at a different anatomic site. In 3 of 21 patients, inflammatory tissue and no tumor were identified. Eighteen of 20 SCC tumors were positive for both 18F-FDG uptake and 18F-FET uptake, one 0.3-cm SCC tumor was detected neither with 18F-FDG PET nor with 18F-FET PET, and one 0.7-cm SCC tumor in a 4.3-cm ulcer was overestimated as a 4-cm tumor on 18F-FDG PET and missed on 18F-FET PET. Inflammatory tissue was positive for 18F-FDG uptake (SUV, 3.7-4.7) but negative for 18F-FET uptake (SUV, 1.3-1.6). The SUVs of 18F-FDG in SCC were significantly higher (13.0 +/- 9.3) than those of 18F-FET (4.4 +/- 2.2). The ROC analysis showed significantly superior detection of SCC with (18)F-FET PET or 18F-FDG PET than with CT. No significant difference (P = 0.71) was found between 18F-FDG PET and 18F-FET PET. The sensitivity of 18F-FDG PET was 93%, specificity was 79%, and accuracy was 83%. 18F-FET PET yielded a lower sensitivity of 75% but a substantially higher specificity of 95% (accuracy, 90%).
Conclusion:
18F-FET may not replace 18F-FDG in the PET diagnostics of head and neck cancer but may be a helpful additional tool in selected patients, because 18F-FET PET might better differentiate tumor tissue from inflammatory tissue. The sensitivity of 18F-FET PET in SCC, however, was inferior to that of 18F-FDG PET because of lower SUVs.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET