Related Experiment Video
Updated: Aug 11, 2026

Proteomic Sample Preparation from Formalin Fixed and Paraffin Embedded Tissue
Published on: September 2, 2013
Pre-extraction sample handling by automated frozen disruption significantly improves subsequent proteomic analyses
R Hussain Butt1, Jens R Coorssen
1Department of Physiology & Biophysics, Faculty of Medicine, University of Calgary, Calgary, AB, Canada.
Abstract:
Here we quantitatively characterize two common homogenization strategies in the analysis of tissue proteomes: classical manual homogenization (MH) and an automated frozen disruption (AFD) technique. In a variety of tissues, many proteins were more efficiently extracted, resolved and detected, with high reproducibility after AFD, amounting to as much as 2% of the total resolved proteome. The benefits of AFD over MH are 2-fold: (1) AFD yields a much more thorough homogenate than MH; and (2) as a deep frozen alternative, AFD maintains a level of biological complexity that is not retained during MH. Thus, AFD coupled with refined 2DE protocols and Sypro Ruby staining yields quantitative proteomic analyses.