The sphygmograph in America: writing the pulse
1Robert Wood Johnson Medical School, Piscataway, New Jersey, USA. moss.sandra@gmail.com
Abstract:
The sphygmograph (literally a "pulse writer") was 1 of the first "instruments of precision" to be used in examining the cardiovascular system. In the 1860s and 1870s, some physiologically oriented American practitioners began using European sphygmographs to evaluate patients with a variety of cardiovascular and other disorders, study the action of drugs, assess arterial tension, and determine what was referred to as the "state of the circulation." Three previously unrecognized Americans modified existing European models or constructed original instruments of their own design. Two of these American "sphygmograph men" published the results of their novel experimental work, and the third produced a successful commercial model. Despite early expectations that the sphygmograph would reveal precise information about cardiovascular disease, the various models proved frustrating to use in practice. Recorded sphygmograms defied precise interpretation and correlation with clinical and pathologic findings. The sphygmograph, which faded from practice by the 1890s, helped prepare practitioners for more durable technologies such as the sphygmomanometer and electrocardiograph, which entered practice early in the 20th century. The sphygmograph and its American champions were overshadowed and quickly forgotten.
More Related Videos
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
05:51Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Regulation of Pulse
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...