Related Experiment Video
Updated: Aug 11, 2026

The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
Validity of infrared thermal measurements of segmental paraspinal skin surface temperature
Richard Roy1, Jean P Boucher, Alain S Comtois
1Module Chiropratique, Université du Québec à Trois-Rivières, Trois-Rivières, Quebec, Canada.
Objective:
The purpose of this study was to evaluate the validity of thermal measurements by infrared camera thermometry.
Methods:
Seventeen subjects underwent a 30-minute acclimatizing period in a controlled environment room. Thermal recordings were executed at the levels of C4 and L4. Fifteen recordings per segment were acquired in an alternating mode that always started at L4. Each subject was required to participate on 5 occasions. The exclusion criteria for the subjects included the following: no inflammatory disease or fever, no consumption of beverages containing caffeine, and no participation in physical activity 2 hours before the recording session; female subjects could not be menstruating on a day of recording.
Results:
A total of 2550 recordings for the cervical area and the lumbar area was recorded. Strong significant correlations were found for the left (r = .77) and right (r = .71) lumbar sections (P < .0001) whereas weaker significant correlations were observed for the left (r = .56) and right (r = .63) cervical areas (P < .0001). The limits of agreement (Bland-Altman) showed good relationships but poor interchangeability.
Conclusions:
In this study, the infrared cameras showed that they were valid tools in a controlled environment; however, the technique for the cervical measurements needs to be reassessed.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Thermosensation
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...