Does 18F-FDG PET/CT play a role in the differential diagnosis of parotid masses
D Rubello1, C Nanni, P Castellucci
1Department of Nuclear Medicine, S. Maria della Misericordia Hospital, Rovigo, Italy. domenico.rubello@libero.it
Aim:
The aim of the present study was to assess the accuracy of an hybrid PET/CT scanner in the evaluation of newly diagnosed parotid masses, comparing the results with those reported in the literature with using PET scanners only.
Methods:
The potential role of 18F-FDG PET/CT in distinguishing benign from malignant parotid masses in 14 consecutive patients was investigated. All patients were preoperatively evaluated by means of ultrasound (US), US-guided fine needle aspiration (FNA) cytology, computed tomography (CT) scan, magnetic resonance imaging (MRI) and 18F-FDG PET/CT. For To interpreting FDG PET findings, the right to left parotid (R/L) SUV max ratio was calculated in a group of 54 patients without evidence of parotideal disease (mean+/-SD = 1+/-0.2; range = 0.8-1.2); considering the R/L SUV max ratio, focal or diffuse uptakes <0.8 or >1.2 were considered as potentially pathological.
Results:
Imaging data were compared with surgical and histopathological findings. At FDG PET/CT, 9 false positive cases were found (8 Warthin's tumours, 1 pleomorphic adenoma), 1 false negative (acinar cell carcinoma), 4 true negative (1 Warthin's tumour, 1 pleomorphic adenoma, 1 lymph epithelial cyst, 1 parotid inflammation) whereas there was no case of true positive. The global accuracy of FGD PET/CT was rather low = at 29%.
Conclusions:
In agreement with other preliminary reports in which the FDG PET without CT fusion imaging was used, in our experience 18F-FDG PET/CT did not prove to play a significant role in differential diagnosis (benign vs malignant) of parotid masses. Further studies collecting larger groups of patients are needed to further elucidate this observation.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...