Related Experiment Video
Updated: Aug 11, 2026

An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
Monitoring of iodinated X-ray contrast media in surface water
Wolfram Seitz1, Walter H Weber, Jia-Qian Jiang
1Zweckverband Landeswasserversorgung, Betriebs- und Forschungslaboratorium, Am Spitzigen Berg 1, D-89129 Langenau, Germany.
Abstract:
A monitoring programme was carried out in order to determine iodinated X-ray contrast media (ICM) in the River Danube and to investigate the raw water quality for drinking water production at Langenau waterworks. The study revealed that the maximum concentrations of ICM (over 500 ng l(-1) for diatrizoic acid and iopamidol) were found in 2h-composite samples taken from the downstream of the Ulm/Neu-Ulm metropolitan area. By means of a concentration profile over one month the highest ICM concentrations were observed on weekdays. The extended data evaluation with principal component analysis shows that the upstream and downstream samples had different pattern of variations in ICM concentration and also demonstrates a clear change in ICM composition by the discharge of municipal wastewater. In addition to load profiles of ICM, time-dependent plots of principal component 1 exhibited peaks, indicating a short-term discharge of ICM between the two sampling sites. In conclusion, a point source for ICM contamination between the sampling sites in Ulm upstream and Leipheim downstream seems to be the reasonable explanation for peak ICM concentrations. Due to the observed high variations of ICM concentrations in river, the evaluation of natural waters by means of a single analysis is not representative.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Redox Titration: Iodimetry and Iodometry
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan: