Related Experiment Video
Updated: Aug 11, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Using combined x-ray and MR imaging for prostate I-125 post-implant dosimetry: phantom validation and preliminary
M E Miquel1, K S Rhode, P L Acher
1Division of Imaging Sciences, King's College London, London, SE1 9RT, UK.
Abstract:
Post-implantation dosimetry is an important element of permanent prostate brachytherapy. This process relies on accurate localization of implanted seeds relative to the surrounding organs. Localization is commonly achieved using CT images, which provide suboptimal prostate delineation. On MR images, conversely, prostate visualization is excellent but seed localization is imprecise due to distortion and susceptibility artefacts. This paper presents a method based on fused MR and x-ray images acquired consecutively in a combined x-ray and MRI interventional suite. The method does not rely on any explicit registration step but on a combination of system calibration and tracking. A purpose-built phantom was imaged using MRI and x-rays, and the images were successfully registered. The same protocol was applied to three patients where combining soft tissue information from MRI with stereoscopic seed identification from x-ray imaging facilitated post-implant dosimetry. This technique has the potential to improve on dosimetry using either CT or MR alone.