Related Experiment Video
Updated: Jul 1, 2026

Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Analytical and semipreparative resolution of ranolazine enantiomers by liquid chromatography using polysaccharide
Xingping Luo1, Zongde Zhai, Xiaomei Wu
1Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou, PR China.
Abstract:
Novel HPLC methods were developed for the analytical and semipreparative resolution of new antianginal drug ranolazine enantiomers. Good baseline enantioseparation was achieved using cellulose tris (3,5-dimethylphenylcarbamate) (CDMPC) chiral stationary phases (CSPs) under both normal-phase and polar organic modes. The validation of the analytical methods including linearity, LODs, recovery, and precision, and the semipreparative resolution of ranolazine racemate were carried out using methanol as mobile phase without any basic and acidic additives under polar organic mode, using CDMPC CSPs. At analytical scale, the elution times of both enantiomers were less than 7.5 min at 20 degrees C and 1.0 mL/min, with the separation factor (a) 1.88 and the resolution factor (R(s)) 2.95. At semipreparative scale, about 14.3 mg/h enantiomers could be isolated and elution times of both enantiomers were less than 13 min at 2.0 mL/min. To increase the throughput, the technique of overlapping injections was used. The first eluted enantiomer was isolated with a purity of 99.6% enantiomer excess (e.e.) and > 99.0% yield. The second enantiomer was isolated with a purity of 98.8% e.e. and > 99.0% yield. In addition, optical rotation and circular dichroism spectroscopy of both ranolazine enantiomers isolated were also investigated.
Related Concept Videos
Racemic Mixtures and the Resolution of Enantiomers
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography

