Abstract:
The atomic-scale stability of clean silicon tips used in noncontact atomic force microscopy (NC-AFM) is simulated by ab initio calculations based on density functional theory. The tip structures are modeled by silicon clusters with and termination. For the often assumed Si(111)-type tip we observe the sharpening of the initially blunt tip via short-range chemical forces during the first approach and retraction cycle. The structural changes corresponding to this intrinsic process are irreversible and lead to stable NC-AFM imaging conditions. In opposition to the picture used in literature, the Si(001)-type tip does not exhibit the so-called "two-dangling bond" feature as a bulklike termination suggests.