Related Experiment Video
Updated: Aug 11, 2026

Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
Echocardiography versus right-sided heart catheterization among lung transplantation candidates
Itsik Ben-Dor1, Mordechai R Kramer, Avraham Raccah
1Department of Cardiology, Pulmonology Institute and Cardiothoracic Surgery, Rabin Medical Center, Tel Aviv University, Israel.
Background:
Right-heart-catheterization and transthoracic echocardiography are routine tests to measure pulmonary artery systolic pressure among lung transplantation candidates. Echocardiography may be as accurate as right-heart-catheterization, without the inherent risks of an invasive test.
Methods:
We examined the correlation between pulmonary pressures estimated by echocardiography versus right-heart-catheterization among lung transplantation candidates and their correlation to measurements during lung transplantation. Our cohort included all lung transplantation candidates during 1997 through 2004 who initially underwent pulmonary pressure evaluation by right-heart-catheterization and echocardiography, as well as measurements during lung transplantation.
Results:
Of the 106 candidates, evaluation by transthoracic echocardiography was possible in 79 (74.5%). Median pulmonary systolic pressures by right-heart-catheterization was 44.0 [33.2-50.0] mm Hg and by echocardiography 40.0 [32.5-51.5] mm Hg (r = 0.80, p < 0.0001). In 14 (17.7%) patients the difference between the 2 methods was > 20 mm Hg. The median time interval between echocardiography and right-heart-catheterization was 65 [40-155] days. The median value of pulmonary systolic pressure measured during lung transplantation in 44 (70.1%) of 62 patients was 39.5 [31.0-50.0] mm Hg. The time interval right-heart-catheterization-to-lung transplantation was 143 [87-339] days and echocardiography-to-lung transplantation 229 [130-367] days. The correlation between measurements during lung transplantation and initial measurements by right-heart-catheterization and echocardiography were r = 0.50 and r = 0.31, respectively, with corresponding p values of p = 0.001 and p = 0.07.
Conclusions:
For lung transplantation candidates and a suitable transthoracic echocardiography estimate of pulmonary systolic pressure, the need for right-heart catheterization, with its inherent risks for complications, may be foregone. The weak correlation between the initial and intraoperative measurements, probably stemming from the significant time interval, suggests that serial measurements may be needed.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Acute Coronary Syndrome III: Diagnostic Studies