Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Recent developments in X-ray imaging with micrometer spatial resolution.

Thierry Martin1, Andreas Koch

  • 1European Synchrotron Radiation Facility (ESRF), BP 220, 38043 Grenoble, France. tmartin@esrf.fr

Journal of Synchrotron Radiation
|February 24, 2006
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Relapse risk of lupus-related serositis according to immunosuppressive therapy: a national real-world study.

RMD open·2026
Same author

Safety and efficacy of blinatumomab in the treatment of refractory systemic sclerosis: a case series.

Annals of the rheumatic diseases·2026
Same author

Scaling up X-ray holographic nanotomography for neuronal tissue imaging.

Biomedical optics express·2026
Same author

Lasing of a cavity-based X-ray source.

Nature·2026
Same author

Comparison of disease severity and activity between juvenile- and adult-onset dermatomyositis: a multicentre cohort study.

Rheumatology (Oxford, England)·2026
Same author

Cold-induced stress responses during a self-rescue exercise from accidental immersion in ice water in military personnel.

Frontiers in physiology·2025

Researchers developed advanced X-ray detectors using novel scintillators for high-resolution imaging. These detectors improve X-ray absorption, reducing exposure times for faster, clearer imaging applications.

Area of Science:

  • Materials Science
  • Physics
  • Imaging Technology

Background:

  • X-ray detectors utilizing scintillators, optics, and charge-coupled devices (CCDs) have enabled micrometer-scale imaging at synchrotron sources since 1996.
  • Current detectors achieve 0.5 microm FWHM resolution but are limited by low X-ray absorption in thin scintillators, necessitating longer exposure times.

Purpose of the Study:

  • To enhance X-ray absorption in scintillators for improved detective quantum efficiency and reduced exposure times.
  • To investigate novel scintillator materials and fabrication methods for advanced X-ray detection.
  • To demonstrate a fast microtomography experiment utilizing the developed detector system.

Main Methods:

  • Investigated new scintillator materials including Lu2O3:Eu3+, Gd2O3:Eu3+, Lu2SiO5:Ce, Gd3Ga5O12:Eu3+, and CdWO4.

Related Experiment Videos

  • Fabricated scintillators using sol-gel and liquid-phase epitaxy processes.
  • Integrated scintillators with light microscopy optics and CCD cameras for X-ray detection.
  • Main Results:

    • Achieved 0.5 microm FWHM resolution with a 1 microm-thick europium-doped Lu3Al5O12 film scintillator.
    • Explored new scintillator compositions to increase X-ray absorption.
    • Demonstrated the first fast microtomography experiment with radiation-hard optics, using a 60 keV white beam and a 60 frames/s CCD camera.

    Conclusions:

    • Novel scintillators fabricated via sol-gel and liquid-phase epitaxy show promise for enhancing X-ray detector performance.
    • Increased X-ray absorption in scintillators is crucial for reducing exposure times and improving imaging efficiency.
    • The developed detector system enables rapid, high-resolution microtomography with improved radiation hardness.