Differential-phase-shift quantum key distribution with an extended degree of freedom

Toshimori Honjo1, Kyo Inoue

  • 1NTT Basic Research Laboratories, NTT Corporation, Atsugi-shi 243-0198, Japan. honjo@will.brl.ntt.co.jp

Optics Letters
|February 25, 2006
PubMed

Related Concept Videos

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
Properties of Fourier Transform II01:24

Properties of Fourier Transform II

The Fourier Transform (FT) is an essential mathematical tool in signal processing, transforming a time-domain signal into its frequency-domain representation. This transformation elucidates the relationship between time and frequency domains through several properties, each revealing unique aspects of signal behavior.
The Frequency Shifting property of Fourier Transforms highlights that a shift in the frequency domain corresponds to a phase shift in the time domain. Mathematically, if x(t) has...
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Transmission-Line Differential Equations01:26

Transmission-Line Differential Equations

Transmission lines are essential components of electrical power systems. They are characterized by the distributed nature of resistance (R), inductance (L), and capacitance (C) per unit length. To analyze these lines, differential equations are employed to model the variations in voltage and current along the line.
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from the...
Extended Versions of Green’s Theorem01:27

Extended Versions of Green’s Theorem

Green’s Theorem connects the circulation of a vector field around a closed curve with the behavior of the field across the region enclosed by that curve. It provides a way to replace a line integral around a boundary with a double integral over the interior region, making it especially useful in plane geometry, fluid flow, and vector calculus.Although Green’s Theorem is often introduced using simple regions without gaps, it can also be applied to regions made from several simple parts. This...