Related Experiment Video
Updated: Aug 11, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Multi-detector row CT angiography of pulmonary circulation with gadolinium-based contrast agents: prospective
Martine Remy-Jardin1, Julbert Bahepar, Jean-Jacques Lafitte
1Departmentsof Radiology, Calmette Hospital, University Center of Lille, France. mremy-jardin@chru-lille.fr
Purpose:
To prospectively evaluate gadolinium dose safety and effectiveness for 16-detector pulmonary computed tomographic (CT) angiography.
Materials And Methods:
Ethics committee approval and informed consent were obtained. Sixty patients with contraindications to iodine underwent CT of the pulmonary circulation with 0.5 mmol/L gadolinium chelate given at either 0.3 (n = 29, group A) or 0.4 (n = 31, group B) mmol/kg; clinical and biologic tolerances were evaluated. Enhancement of central and segmental pulmonary arteries was measured (poor enhancement, <100 HU; good, 100-150 HU; excellent, >150 HU). Subsegmental artery enhancement was assessed as similar or inferior to that of segmental arteries. Confidence in analysis of the pulmonary arterial bed was graded according to arterial enhancement: Grades 1-3, diagnostic images; grade 4, nondiagnostic. The main effectiveness parameter for comparison between groups A and B was diagnostic value of CT angiograms. Nonparametric statistics were used to analyze results.
Results:
The mean (+/- standard deviation) contrast material volume was 50.09 mL +/- 8.45 (all patients: range, 30-64 mL; group A: 46.54 mL +/- 8.59; group B: 53.42 mL +/- 6.92). Diagnostic images were obtained in 55 (92%) patients, and confident analysis of pulmonary arteries to the subsegmental level was achieved in 26 (grade 1, 44%) and to the segmental level, in 21 (grade 2, 35%). Mean attenuation was higher in group B than in group A in central (180.61 HU +/- 53.85 vs 148.14 HU +/- 52.61; P = .04) and segmental (201.59 HU +/- 54.70 vs 164.73 HU +/- 59.26; P = .03) arteries. Number of diagnostic CT angiograms was higher (P = .02) in group B (n = 31 [100%]) than in group A (n = 24 [83%]). In both groups, mean enhancement of pulmonary arteries was significantly higher at 80 or 100 kV than at 120 kV. Renal function was impaired in two group A patients.
Conclusion:
Gadolinium chelates may be used as an alternative CT contrast agent in patients who cannot receive iodine.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Radiological Investigation I: X-ray and CT
