Related Experiment Video
Updated: Aug 11, 2026

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
High-Level Mobility Assessment Tool (HiMAT): interrater reliability, retest reliability, and internal consistency
Gavin P Williams1, Kenneth M Greenwood, Val J Robertson
1Physiotherapy Department, Epworth Hospital, Richmond 3121, Melbourne, Victoria, Australia. gavinw@epworth.org.au
Background And Purpose:
The High-Level Mobility Assessment Tool (HiMAT) assesses high-level mobility in people who have sustained a traumatic brain injury (TBI). The purpose of this study was to investigate the interrater reliability, retest reliability, and internal consistency of data obtained with the HiMAT.
Subjects:
Three physical therapists and 103 people with TBI were recruited from a rehabilitation hospital.
Methods:
Three physical therapists concurrently assessed a subset of 17 subjects with TBI to investigate interrater reliability. One physical therapist assessed a different subset of 20 subjects with TBI on 2 occasions, 2 days apart, to investigate retest reliability. Data from the entire sample of 103 subjects were used to investigate the internal consistency of this new scale.
Results:
Both the interrater reliability (intraclass correlation coefficient [ICC]=.99) and the retest reliability (ICC=.99) of the HiMAT data were very high. For retest reliability, a small systematic change was detected (t=3.82, df=19), indicating a marginal improvement of 1 point at retest. Internal consistency also was very high (Cronbach alpha=.97).
Discussion And Conclusion:
The HiMAT is a new tool specifically designed to measure high-level mobility, which currently is not a component of existing scales used in TBI. This study demonstrated that the HiMAT is a reliable tool for measuring high-level mobility.