Related Experiment Video
Updated: Aug 11, 2026

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
[Non-ionic iodinated dimeric versus monomeric X-ray contrast media: effects on complement factors in vivo]
1Radiologische Universitätsklinik, Rheinische Friedrich-Wilhelms-Universität. ingrid.boehm@ukb.uni-bonn.de
Insights
Contrast media (CM) injections can alter complement factors, with dimeric iotrolan causing more reactions than monomeric iopromide. These effects were transient, typically resolving within 30 minutes post-injection.
Area of Science:
- Radiology and Imaging
- Immunology
- Pharmacology
Background:
- Contrast media (CM) are essential in medical imaging.
- CM can elicit adverse reactions, including complement activation.
- Understanding CM-induced immunological responses is crucial for patient safety.
Purpose of the Study:
- To investigate contrast media (CM)-induced alterations of complement factors.
- To compare the effects of iotrolan and iopromide on complement pathways.
Main Methods:
- Serum samples from 31 patients receiving iotrolan or iopromide for CT scans were analyzed.
- Complement factors (C1q, C3, C4, C5a, C1-esterase inhibitor) were measured pre- and post-CM injection at various time points.
- Incidence of CM reactions was recorded.
Main Results:
- 16.1% of patients experienced CM reactions, with 4/5 occurring in the iotrolan group.
- CM administration showed a transient tendency for complement factor levels to decrease, returning to baseline within 30 minutes.
- Iotrolan induced more pronounced, though not statistically significant, changes in C3 and C4 compared to iopromide, suggesting potential classical pathway activation.
Conclusions:
- CM injection transiently affects complement factors, with most changes resolving within 30 minutes.
- Dimeric iotrolan was associated with a higher frequency of adverse reactions compared to monomeric iopromide.
- Further research with larger patient cohorts is needed to confirm if iotrolan activates the classical complement pathway.
Purpose:
To survey contrast media (CM)-induced alterations of complement factors.
Material And Methods:
In 31 adult patients, who received either an iotrolan (n = 19) or iopromide (n = 12) i. v. injection for CT examination, complement factors C1 q, C3, C4, C5 a, and C1-esterase inhibitor in serum/plasma samples were analyzed. The samples were obtained prior to and 5 min., 30 min., 1 hr., 6 hrs. and 24 hrs. after CM injection.
Results:
5 patients (16.1 %) developed a CM reaction. 4 of these were patients who received iotrolan. Other than minimal data, we neither found a significant influence of the CM on complement activation nor a difference between the analyzed CM. In detail, 5 min. after CM administration, we found the tendency to be for the values to decrease and then to return to the basic value. The changes induced by iotrolan were more pronounced than those induced by iopromide; nevertheless the differences were not statistically significant. A more pronounced decrease of C3 and C4 after iotrolan injection indicates the activation of the classic way, while this could not been observed after iopromide injection. One patient who experienced an unwanted reaction towards iotrolan showed shifts of C1 q, C1 INH, C3 and C4.
Conclusion:
The presented data shows different influences of CM injection on the analyzed complement factors after 5 min. that were commonly no longer present 30 min. after CM injection. The dimeric iotrolan induced a significantly increased frequency of unwanted CM reactions than the monomeric iopromide. The question of whether iotrolan is possibly able to activate the classic way of the complement cascade should be analyzed in the future in a greater patient group.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
X-ray Imaging
Common Ion Effect
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Formation of Complex Ions