Related Experiment Videos
An investigation into the use of a single component self-etching primer adhesive system for orthodontic bonding: a
K House1, A J Ireland, M Sherriff
1Department of Child Dental Health, Bristol Dental Hospital, Bristol BS1 2LY, UK.
Objective:
This study assessed the in vivo bond failure of the single component orthodontic self-etching primer system, Ideal 1 (GAC Orthodontic Products) and compared it with the conventional acid etching using a conventional 37% o-phosphoric acid, rinsing and drying regimen when bonding stainless steel orthodontic brackets to enamel.
Design:
Prospective randomized, controlled clinical trial.
Setting:
Orthodontic Department, Bristol Dental School.
Material And Methods:
Twenty consecutive patients undergoing upper and lower fixed orthodontic treatment entered this cross-mouth control study. Diagonally opposite quadrants were randomly allocated to either the self-etching primer group or the conventional etching group. A total of 339 teeth were bonded with Ideal 1 light-cured adhesive. Bond failures and locus of bond failure were then recorded at 1, 6 and 12 months.
Results:
Significantly more bond failures occurred at each of the 3 time intervals, 1, 6 and 12 months, where the enamel was pretreated with the Ideal I self-etching primer, than when the enamel was treated with the conventional etchant, 37% o-phosphoric acid. With the latter the cumulative bond failure rates were 3.0, 5.3 and 14.8%, respectively. With the self-etching primer the cumulative failure rates were 29.4, 56.5 and 72.4%.
Conclusion:
The study found that enamel pre-treatment with the Ideal 1 self-etching primer system prior to orthodontic bonding results in an unacceptably high bond failure rate when compared with conventional enamel acid etching.