Related Experiment Video
Updated: Aug 11, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Value of noninvasive hemodynamics to achieve blood pressure control in hypertensive subjects
Ronald D Smith1, Pavel Levy, Carlos M Ferrario
1Hypertension and Vascular Disease Center, Wake Forest University School of Medicine, Winston-Salem, NC 27157-1032, USA.
Insights
Hypertension therapy guided by impedance cardiography (IC) significantly improved blood pressure control in uncontrolled hypertensive patients. This noninvasive hemodynamic monitoring offers a more effective approach than standard care for managing high blood pressure.
Area of Science:
- Cardiovascular Medicine
- Hypertension Research
- Medical Technology
Background:
- Abnormal hemodynamics are integral to the development and persistence of high blood pressure.
- Current hypertension management may not fully leverage hemodynamic insights for optimal patient outcomes.
Purpose of the Study:
- To evaluate if hypertension therapy guided by noninvasive hemodynamics using impedance cardiography (IC) improves blood pressure reduction efficacy compared to standard care.
- To assess the impact of IC-guided therapy on achieving target blood pressure goals in patients with uncontrolled hypertension.
Main Methods:
- A randomized controlled trial involving 164 patients with uncontrolled hypertension on 1-3 medications.
- Patients were assigned to either a standard care arm or a hemodynamic arm utilizing impedance cardiography (BioZ, CardioDynamics).
- Therapy was administered over 3 months following a 2-week washout period, with 5 study visits per patient.
Main Results:
- The hemodynamic arm demonstrated significantly greater reductions in both systolic (19 mm Hg vs. 11 mm Hg) and diastolic blood pressure (12 mm Hg vs. 5 mm Hg) from baseline.
- Greater blood pressure reductions were also observed in the hemodynamic arm after washout (Systolic: 25 mm Hg vs. 19 mm Hg; Diastolic: 17 mm Hg vs. 10 mm Hg).
- Patients in the hemodynamic arm achieved goal blood pressure (<140/90 mm Hg) more frequently (77% vs. 57%) and a more aggressive target (<130/85 mm Hg) more frequently (55% vs. 27%).
Conclusions:
- Antihypertensive therapy guided by impedance cardiography is more effective than standard care for uncontrolled hypertensive patients on medication.
- Noninvasive hemodynamic monitoring can empower primary care physicians to more effectively manage and reduce blood pressure in hypertensive patients.
Abstract:
Abnormal hemodynamics play a central role in the development and perpetuation of high blood pressure. We hypothesized that hypertension therapy guided by noninvasive hemodynamics with impedance cardiography could aid primary care physicians in reducing blood pressure more effectively. Uncontrolled hypertensive patients on 1 to 3 medications were randomized by 3:2 ratio to either a standard arm or hemodynamic arm that used impedance cardiography (BioZ, CardioDynamics). Each patient completed 5 study visits with a 2-week washout period followed by 3 months of treatment. A total of 164 patients from 11 centers completed the study, 95 in the standard arm and 69 in the hemodynamic arm. At baseline and after washout, there were no differences between arms in number of medications or demographic, blood pressure, or hemodynamic characteristics. Systolic blood pressure reductions in the hemodynamic arm were greater from baseline (19 mm Hg versus 11 mm Hg; P<0.01) and after washout (25 mm Hg versus 19 mm Hg; P<0.05). Diastolic blood pressure reductions were also greater in the hemodynamic arm from baseline (12 mm Hg versus 5 mm Hg; P<0.001) and after washout (17 mm Hg versus 10 mm Hg; P<0.001). The hemodynamic arm achieved goal blood pressure (<140/90 mm Hg) more frequently (77% versus 57%; P<0.01) and a more aggressive blood pressure level (<130/85 mm Hg) more frequently (55% versus 27%; P<0.0001). These study results indicate that antihypertensive therapy guided by impedance cardiography in uncontrolled hypertensive patients on >/=1 medications is more effective than standard care.
Related Concept Videos
Hypertension and Regulation of Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the diastolic...
Blood Pressure
Hypertension III: Clinical Manifestations and Diagnostic Studies
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Hypertension V: Nursing Management