Engineering risk analysis of a hospital oxygen supply system
Léa A Deleris1, Gee Liek Yeo, Adam Seiver
1Department of Management Science and Engineering, Stanford University, Stanford, CA 94305, USA.
Abstract:
Reports from the Food and Drug Administration (FDA) and the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) have emphasized the potential for injury to patients caused by failures in oxygen supply systems. This article presents a model of patient risk related to the process of supplying oxygen at a single university hospital. One of the goals of the article is to illustrate how probabilistic risk analysis (PRA) can be used by hospitals to assess and mitigate risk and, therefore, to meet JCAHO requirements. PRA techniques are useful to 1) model the reliability of a complex system and 2) assess the cost-effectiveness of different risk mitigation measures. The authors focus on the risk estimation step, describing in detail their modeling of the oxygen supply system and analysis of the results. For the hospital that the authors study (20,000 admissions yearly), the total expected number of fatalities from oxygen system failure is 44 over a 30-year time horizon. The greatest contribution to the risk (94% of the expected number of fatalities) comes from problems that involve the supply network (e.g., damage to structure and poisoning) as opposed to incidents that occur inside patient rooms. Although the threat to patient safety is not dramatic, health care organizations should be concerned about potential failures of their oxygen system because improving this system could avoid low-probability, high-consequence failures at a low cost.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Requirements and Growth Patterns
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...