Electroencephalographic staging of hepatic encephalopathy by an artificial neural network and an expert system
A Pellegrini1, E Ubiali, R Orsato
1Clinica Medica 5, Università di Padova, Viale Giustiniani 2, 35128 Padova, Italy.
Aim Of The Study:
To provide an objective EEG assessment of hepatic encephalopathy (HE), we set up and tested an entirely automatic procedure based on an artificial neural network-expert system software (ANNESS).
Patients And Methods:
A training set sample of 50 EEG (group A) and a test sample of 50 EEG (group B) of 100 cirrhotic patients were considered. The EEGs had been visually classified by an expert electroencephalographer, using a modified five-degree Parsons-Simith classification of HE. The efficiency of the ANNESS, trained in group A, was tested in group B.
Results:
Both the ANNESS and the visually-based classifications were found to be correlated to liver insufficiency, as assessed by the Child-Pugh score (Spearman's coefficient rho=0.485, P<0.0001; rho=0.489, P<0.0001, respectively) and by the biochemical indexes of hepatic function (bilirubin: rho=0.31 vs. 0.27; albumin: rho=-0.13 vs. -0.18; prothrombin time rho=-0.35 vs. -0.52). The classifications were found to be correlated to each other (rho=0.84 P<0.0001, Cohen's kappa=0.55). However, the ANNESS overestimated grade 2 EEG alterations.
Conclusion:
An ANNESS-based classification of EEG in HE provided data comparable with a visually-based classification, except for mild alterations (class 2) that tended to be overestimated. Further optimization of automatic EEG staging of HE is desirable, as well as a prospective clinical evaluation.