Prediction of aortic augmentation index using radial pulse transmission-wave analysis
Elizabeth O Y Lau1, Hung-Fat Tse, Raymond H W Chan
1Department of Medicine, The University of Hong Kong.
Objective:
Current arterial transfer functions have low capability in predicting aortic augmentation index (AIx) from radial pulse contour (RPC), because of the difficulty in accurately identifying the merging point (inflection point) in the derived aortic pulse contour (APC). We hypothesize that the formation time between each characteristic wave in APC is about one-third of ejection duration (ED/3). We sought to assess the accuracy of ED/3 in identifying the merging point in APC as compared to the conventional differential method. In addition, we sought to derive the AIx from RPC based on an arterial transfer function and the ED/3 method.
Methods:
APC and RPC sequences were measured digitally and simultaneously in 60 subjects (37 males; aged 60 +/- 10 years). An ensemble-averaged RPC-to-APC transfer function was determined from 30 randomly selected subjects and was used to derive APC sequences in the 30 additional subjects. The accuracy of AIx predicted from RPC was determined.
Results:
In patients with a clearly identifiable merging point in APC, the ED/3 method identified the merging point of measured APC within 1.97 +/- 0.60 ms of that identified by the conventional differential method, with identical AIx. The AIx and merging point of derived APC using the ED/3 method were also within 0.22 +/- 1.01% and 1.81 +/- 1.64 ms, respectively, of those of the measured APC using the conventional differential method. The accuracy of the predicted AIx was independent of age, sex, body-mass index and presence of hypertension.
Conclusion:
In a quiet resting state, the ED/3 is an alternative method for identifying the merging point in APC. In conjunction with transfer-function technique, AIx can be derived accurately from RPC.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse
The pulse serves as a clinical indicator...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: