Cortical bone viscoelasticity and fixation strength of press-fit femoral stems: finite element model
T R Shultz1, J D Blaha, T A Gruen
1National Energy Technology Laboratory, 3610 Collins Ferry Road, P.O. Box 880, MS D06, Morgantown, WV 26507-0880, USA.
Abstract:
Many cementless implant designs rely upon a diaphyseal press-fit in conjunction with a porous coated implant surface to achieve primary or short term fixation, thereby constraining interface micromotion to such a level that bone ingrowth and consequent secondary or long-term fixation, i.e., osseointegration, can occur. Bone viscoelasticity, however, has been found to affect stem primary stability by reducing push-out load. In this investigation, an axisymmetric finite element model of a cylindrical stem and diaphyseal cortical bone section was created in order to parametrically evaluate the effect of bone viscoelasticity on stem push-out while controlling coefficient of friction (mu = 0.15, 0.40, and 1.00) and stem-bone diametral interference (delta = 0.01, 0.05, 0.10, and 0.50 mm). Based on results from a previous study, it was hypothesized that stem-bone interference (i.e., press-fit) would elicit a bone viscoelastic response which would reduce the initial fixation of the stem as measured by push-out load. Results indicate that for all examined combinations of mu and delta, bone viscoelastic behavior reduced the push-out load by a range of 2.6-82.6% due to stress relaxation of the bone. It was found that the push-out load increased with mu for each value of delta, but minimal increases in the push-out load (2.9-4.9%) were observed as delta was increased beyond 0.10 mm. Within the range of variables reported for this study, it was concluded that bone viscoelastic behavior, namely stress relaxation, has an asymptotic affect on stem contact pressure, which reduces stem push-out load. It was also found that higher levels of coefficient of friction are beneficial to primary fixation, and that an interference "threshold" exists beyond which no additional gains in push-out load are achieved.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Bones of the Lower Limb: Femur and Patella
Bone Remodeling and Repair
Normal Strain under Axial Loading
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...