Related Experiment Video
Updated: Aug 10, 2026

Functional Imaging of Brown Fat in Mice with 18F-FDG micro-PET/CT
Published on: November 23, 2012
A simplified method to integrate metabolic images in stereotactic procedures using a PET/CT scanner
Piero Picozzi1, Giovanna Rizzo, Claudio Landoni
1Department of Neurosurgery, IRCCS, Ospedale San Raffaele, Vita Salute University, Milan, Italy. picozzi.piero@hsr.it
A new method simplifies positron emission tomography (PET) and computed tomography (CT) image coregistration using a CT indicator box. This technique enhances multimodal image fusion accuracy for improved diagnostic imaging.
Area of Science:
- Medical Imaging
- Radiology
- Image Processing
Background:
- Accurate coregistration of positron emission tomography (PET) and computed tomography (CT) images is crucial for integrating functional and anatomical data.
- Existing methods for PET/CT image fusion can be complex and time-consuming.
Observation:
- A novel method utilizes a computed tomography (CT) indicator box for coregistering PET images with CT and magnetic resonance imaging (MRI).
- The procedure involves fixing a stereotactic frame to the patient and positioning them in a PET/CT scanner with the CT indicator box.
- PET images are acquired using [18F]fluorodeoxyglucose or [11C]choline, then exported with CT data in DICOM 3 format.
Findings:
- Homemade software performs multimodal image fusion by overwriting PET image values to corresponding CT points using a threshold algorithm.
- The CT indicator box simplifies the process by eliminating the need for a radioactive solution.
- The localization accuracy of PET images is primarily limited by the slice thickness.
Implications:
- This simplified coregistration method enhances the integration of PET, CT, and MRI data.
- The technique offers improved accuracy for diagnostic imaging and potential applications in image-guided interventions.
- Further validation in diverse clinical scenarios is warranted to fully assess its utility.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET