Related Experiment Video
Updated: Aug 10, 2026
![Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F50301.jpg&w=3840&q=50)
Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
Measuring gastric emptying: comparison of 13C-octanoic acid breath test and scintigraphy
Jari Punkkinen1, Ilmari Konkka, Olli Punkkinen
1Department of Gastroenterology, Helsinki University Hospital, Helsinki, Finland. jari.punkkinen@hus.fi
Abstract:
The aim of this study was to compare scintigraphy, the standard method, and the (13)C-octanoic acid breath test (OBT) for measuring gastric emptying. Patients with functional dyspepsia (N = 21, 8 men and 13 women; ages, 40-75) underwent standardized dynamic scintigraphy and OBT. Scintigraphic images were obtained for 90 min and breath samples for 4 hr. The gastric half-emptying time for solids (T(1/2)) was calculated by two previously described mathematical models for the OBT samples: the nonlinear least-squares method and the geometrical method. T(1/2) was significantly longer measured by OBT than by scintigraphy (167 +/- 50 min for the nonlinear least-squares method (P < 0.05) and 185+/- 52 min for the geometrical method (P < 0.005) vs. 109 +/- 74 min for scintigraphy). No correlation appeared between T(1/2) measured by scintigraphy and T(1/2) measured by OBT (r = 0.26) for nonlinear least-squares method and (r = -0.13) for geometrical method). Furthermore, the correlation between the two mathematical models appeared to be low (r = 0.15). Although OBT is simple and safe, its correlation with scintigraphy appears to be weak. The usefulness of this test for measuring gastric emptying thus requires further validation.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Serum Laboratory Studies, Stool Test, Breath Test
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Gastric Emptying