Related Experiment Video
Updated: Aug 10, 2026

Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Reproducibility of a scoring system for computed tomography scanning in cystic fibrosis
Alan S Brody1, Michael R Kosorok, Zhanhai Li
1Department of Radiology, Cincinnati Children's Hospital, Cincinnati, OH 45229-3039, USA. alan.brody@cchmc.org
Introduction:
Computerized tomography (CT) scanning shows promise as an outcome surrogate for cystic fibrosis (CF) lung disease progression. The scoring system used to convert the CT image to numeric data is an essential determinant of the performance of CT scanning.
Methods:
Three radiologists independently scored 16 high-resolution CT scans performed on children in the Wisconsin CF Neonatal Screening Project. The test scans were selected to provide a broad range of disease severity. The scoring system provided subscores for the presence and severity of 5 findings of CF lung disease. The sum of the subscores provided a total score. The CT scans were then read again by each of the radiologists at least 11 months later. Using Mixed Effects Linear Model Analysis, the sources of error (scan-to-scan variation, interrater variance, and intrarater variance) were calculated.
Results:
For the total score, the scan-to-scan variation was 14.48, interrater variance was 0.28, and intrarater variance was 0.45, with an overall reproducibility of 95%. The square root of scan-to-scan variance, a measure of sensitivity, was 3.81. Evaluation of the subscores showed higher reproducibility for bronchiectasis and hyperinflation (95% and 88%, respectively). The bronchiectasis score was more sensitive than the air-trapping score (1.46 vs. 0.89).
Discussion:
This system was developed to provide a reproducible method that could be used to evaluate the lobar location, severity, and extent of a broad spectrum of CT features of CF lung disease, especially in children. This study demonstrates that the overall score is both sensitive to variation in the severity of lung disease and reproducible.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
