Related Experiment Video
Updated: Jul 5, 2026

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
3D MR coronary angiography: optimization of the technique and preliminary results
Niek Hendrik Jan Prakken1, Evert-Jan P A Vonken, Birgitta K Velthuis
1Department of Radiology, University Medical Centre, Utrecht, The Netherlands. NHJPrakken@GMail.com
Objective:
Current clinical full MR angiography with multiple breathhold multiple thin slab acquisition (MTS) is difficult and arduous. This study describes the optimisation of the whole heart free - breathing balanced turbo field echo (B-TFE) protocol. A high-resolution image of the whole heart is produced in less or comparable time to MTS acquisition and allows for reconstruction afterwards to visualise the individual coronary arteries. The scan is easily performed because the volume has to be targeted only once.
Design And Setting:
Eighteen healthy adults without a history of cardiovascular disease underwent free-breathing 3D MR angiography with the B-TFE protocol. The whole-heart data set was reformatted in identical orientations in all subjects to visualise the major coronary arteries.
Main Outcome Measures:
Vessel length, signal and contrast to noise ratio were determined and compared for each vessel.
Results:
Mean visible vessel lengths were 116 mm for the right, 102 mm for the left main and left descending and 76 mm for the left circumflex coronary artery. The average signal to noise ratio was 7.5 and contrast to noise ratio was 4.9. Because of the need for synchronised cardiac and respiratory triggering the coronaries could not be judged in 25% of the subjects.
Conclusions:
The optimised B-TFE protocol had equal judgeability and vessels could be judged over longer contiguous distances compared to earlier implementations of the B-TFE protocol. We conclude whole heart free breathing navigator-gated and slice-tracked 3D coronary MR angiography with use of the adjusted B-TFE protocol is possible, but still suboptimal for clinical use.
More Related Videos
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 19, 2020
09:57Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies