Dried Blood Spots - Preparing and Processing for Use in Immunoassays and in Molecular Techniques
Published on: March 13, 2015
Antibodies to hepatitis C virus in autologous blood donors
1Institute of Pathology, Case Western Reserve University, Cleveland, Ohio.
Hepatitis C virus (HCV) is the major cause of posttransfusion hepatitis. Two anti-HCV enzyme immunoassay (EIA) kits and one recombinant immunoblot assay (RIBA) were used to test serum samples of 1476 donations from 692 autologous blood donors to assess the prevalence of anti-HCV and its relationship to transfusion history. Of all autologous blood donations, 23 (1.6%) reacted when tested with one EIA kit and 29 (2.0%) reacted when tested by the other EIA kit. Of the autologous donors, 12 (1.78%) reacted by the first EIA kit and 14 (2.02%) by the second. Discrepancies in the EIA results from different donations by the same donor were seen in seven donors. The RIBA was positive or indeterminate in 33 percent of the EIA-reactive donations and in 41 percent of EIA-reactive donors. All RIBA-positive and -indeterminate samples reacted with both EIA kits. There was no significant difference in the EIA-reactive rates of autologous and first-time homologous blood donors. Previously transfused autologous blood donors had a higher anti-HCV EIA-reactive rate than nontransfused autologous donors, but the difference was not significant. In regard to hepatitis C, the use of autologous blood for homologous transfusion appears to be as safe as the use of blood from first-time homologous donors. Universal testing of previously transfused patients for hepatitis C appears premature at this time. Discrepant anti-HCV EIA results from different donations from the same individual have implications regarding donor deferral.
Hepatitis C virus (HCV) is the major cause of posttransfusion hepatitis. Two anti-HCV enzyme immunoassay (EIA) kits and one recombinant immunoblot assay (RIBA) were used to test serum samples of 1476 donations from 692 autologous blood donors to assess the prevalence of anti-HCV and its relationship to transfusion history. Of all autologous blood donations, 23 (1.6%) reacted when tested with one EIA kit and 29 (2.0%) reacted when tested by the other EIA kit. Of the autologous donors, 12 (1.78%) reacted by the first EIA kit and 14 (2.02%) by the second. Discrepancies in the EIA results from different donations by the same donor were seen in seven donors. The RIBA was positive or indeterminate in 33 percent of the EIA-reactive donations and in 41 percent of EIA-reactive donors. All RIBA-positive and -indeterminate samples reacted with both EIA kits. There was no significant difference in the EIA-reactive rates of autologous and first-time homologous blood donors. Previously transfused autologous blood donors had a higher anti-HCV EIA-reactive rate than nontransfused autologous donors, but the difference was not significant. In regard to hepatitis C, the use of autologous blood for homologous transfusion appears to be as safe as the use of blood from first-time homologous donors. Universal testing of previously transfused patients for hepatitis C appears premature at this time. Discrepant anti-HCV EIA results from different donations from the same individual have implications regarding donor deferral.
Related Concept Videos
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Blood Typing
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target antigens A,...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Hepatitis
Viral Hepatitis I: Introduction