Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Solid-liquid distribution of selected concrete admixtures in hardened cement pastes
Martin A Glaus1, A Laube, Luc R Van Loon
1Laboratory for Waste Management, OHLD/002, Paul Scherrer Institut, CH-5232 Villigen, Switzerland. martin.glaus@psi.ch
Abstract:
The distribution between hardened cement paste and cement pore water of selected concrete admixtures (BZMs), i.e., sulfonated naphthalene-formaldehyde condensate (NS), lignosulfonate (LS) and a gluconate-containing plasticiser used at the Paul Scherrer Institute for waste conditioning, was measured. Sorption data were fitted to a single-site Langmuir isotherm with affinity constants K=(19+/-4)dm(3)g(-1) for NS, K=(2.1+/-0.6) dm(3)g(-1) for LS and sorption capacities q=(81+/-16)g kg(-1) for NS, q=(43+/-8)g kg(-1) for LS. In the case of gluconate, a two-site Langmuir sorption model was necessary to fit the data satisfactorily. Sorption parameters for gluconate were K(1)=(2+/-1)x10(6)dm(3)mol(-1) and q(1)=(0.04+/-0.02)mol kg(-1) for the stronger binding site and K(2)=(2.6+/-1.1)x10(3)dm(3)mol(-1) and q(2)=(0.7+/-0.3)mol kg(-1) for the weaker binding site. Desorption of these BZMs from cement pastes and pore water in cement specimens prepared in the presence of the BZMs were then used to test the model. It was found that only minor parts of NS and LS could be mobilised as long as the cement composition was intact, whereas the sorption of gluconate was found to be reversible. The Langmuir model makes valuable predictions in the qualitative sense in that the pore water concentration of the BZMs is reduced by several orders of magnitude as compared to the initial concentrations. In view of the necessity for conservative predictions used in the safety analysis for disposal of radioactive waste, however, the predictions are unsatisfactory in that the measured pore water concentrations of NS and LS were considerably larger than the predicted values. This conclusion does not apply for gluconate, because its concentration in cement pore water was below the detection limit of approximately 50 nM.
More Related Videos
Related Concept Videos
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...
Pore Size Distribution
Adequate...
Superplasticizers
Additives and Fillers in Concrete
The...
Types of Cement II
Plasticizers
Plasticizers function by using surface-active agents to create repulsive electrostatic forces between cement particles. This dispersion enhances the concrete's...