Related Experiment Video
Updated: Aug 9, 2026

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Molecular verification of stereotactic radiotherapy in rats using ATMpS1981 immunofluorescence
Thomas B Brunner1, Antje Ernst-Stecken, Ina Jeske
1Department of Radiation Oncology, University Hospitals of Erlangen, Germany. thomas.brunner@strahlen.imed
Background And Purpose:
Stereotactic radiation therapy and radiosurgery (STS) might be useful for focused treatment in orthotopic tumor models or to evaluate normal tissues. Spatial accuracy of dose-delivery is crucial and needs to be proven. This study intended to show on a molecular level precision of STS using the radiation activated molecule phospho-serine 1981-ATM (ATMpS1981).
Patients And Methods:
Wistar rats underwent MRI fused with CT for treatment with a NOVALIStrade mark (BrainLab) STS device. Rats (body weight = 350 g, respectively) were irradiated with 2 Gy to selected areas of the brain, the lung, the liver, and the pancreas. Animals were sacrificed 1h after STS and organs were explanted for pathohistological workup. Coronal HE-stained sections of treated organs were matched with coronal MRI and CT reconstructions and isodose distributions of STS. Immunofluorescence signal expression in the nuclei after incubation with anti-ATMpS1981 antibody was compared to the target volume of STS.
Results:
Three consecutive animals were treated with STS using 2 Gy single dose which resulted in no apparent changes on HE staining but obvious immunofluorescence signals in irradiated regions. In concordance with isodose distributions these signals had a maximum intensity within the 90% isodose and gradually decreased to a background level with very low nuclear immunofluorescence signals for ATMpS1981. These results were consistent throughout all of the four investigated organs (brain, lung, liver, pancreas) and could be repeated in all of the investigated animals.
Conclusions:
ATMpS1981 immunofluorescence confirms accuracy of STS allowing for partial organ irradiation in small animals. It can be used for quality assurance in STS treatment of normal tissue or orthotopic tumor models.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
05:08Targeted and Selective Treatment of Pluripotent Stem Cell-derived Teratomas Using External Beam Radiation in a Small-animal Model
Published on: February 17, 2019