Related Experiment Video
Updated: Aug 9, 2026

Translational Rabbit Model of Chronic Cardiac Pacing
Published on: January 6, 2023
[Feasibility and safety of long-term AAI(R) pacing in isolated sinus node syndrome]
1Abteilung für Kardiologie, Klinik für Innere Medizin der Universität, Postfach 100888, 18055 Rostock. thomas.koerber@med.uni-rostock.de
Abstract:
Recent investigations prove that AAI(R) pacing is the "ideal" stimulation mode in isolated sick sinus syndrome. Nevertheless, in Germany this bradycardia is treated by AAI(R) pacemakers in less than 4% of cases compared to 25% in other countries. In our institution treatment of patients with isolated sick sinus syndrome is uniform and corresponds to the actual guidelines since the early 1990s; therefore the aim of our study was to analyze feasibility and safety of AAI(R) pacing in a retrospective study. Between 1998 and 2000, 52 of 165 patients (31.5%) with isolated sick sinus syndrome were treated by an AAI(R) pacemaker. The median follow-up duration was 51.5 months (minimal: 36 months). 6 patients died, in all cases unrelated to the stimulation mode. Three patients required reoperations, however, in only one case due to second degree AV block with the need for upgrading to DDD stimulation. Thus, the yearly incidence of this specific complication in the AAI(R) cohort is 0.64%.In conclusion, permanent atrial stimulation in isolated sick sinus syndrome is feasible in a quarter of all cases. It is safe if performed corresponding to actual guidelines. Additionally, single lead AAI(R) pacing is a cost-effective therapy and the only stimulation mode which, today, reliably prevents unnecessary right ventricular stimulation. If, on the other hand, algorithms providing automatic mode switching from AAI to DDD and vice versa are implemented reliably into all dual chamber pacemakers, single chamber atrial pacing will no longer be a subject for discussion.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
10:05Testing the Efficacy of Pharmacological Agents in a Pericardial Target Delivery Model in the Swine
Published on: July 7, 2016
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Dysrhythmias VI: Management of Dysrhythmias
Electrophysiology of Normal Cardiac Rhythm