[Application of 16-slice spiral CT in lower extremity arterial occlusive diseases]
Xiao-dan Zhang1, Zheng-yu Jin, Yan Zhang
1Department of Radiology, PUMC Hospital, CAMS and PUMC, Beijing 100730, China.
Objective:
To determine the diagnostic accuracy of 16-slice spiral CT in assessing the lower extremity arterial occlusive diseases.
Methods:
Thirty patients with suspected peripheral arterial occlusive diseases underwent 16-slice spiral CT angiography (CTA) of lower extremity arteries. All these patients also underwent digital subtraction angiography (DSA) two weeks before or after CTA. CT angiograms were produced using maximal intensity projection, volume rendering technique, and curved planar reconstruction. Using DSA as the standard reference, the diagnostic accuracy of CTA was determined.
Results:
When detecting segments with > or = 50% stenosis, the sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of CTA were 94.3% (115/122), 98.4% (548/557), 97.6% (663/679), 92.7% (115/124), and 98.7% (548/555), respectively.
Conclusion:
16-slice spiral CT has high sensitivity, specificity, and accuracy in detecting lower extremity arterial occlusive diseases and may partially substitute DSA examinations.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Peripheral Artery Disease III: Interprofessional Care