Application of an Amplitude-integrated EEG Monitor (Cerebral Function Monitor) to Neonates
Published on: September 6, 2017
Early low cardiac output is associated with compromised electroencephalographic activity in very preterm infants
Claire R West1, Alan M Groves, Chris E Williams
1Liggins Institute, University of Auckland, Auckland, New Zealand.
Abstract:
Low cerebral blood flow in preterm infants has been associated with discontinuous electroencephalography (EEG) activity that in turn has been associated with poor long-term prognosis. We examined the relationships between echocardiographic measurements of blood flow, blood pressure (BP), and quantitative EEG data as surrogate markers of cerebral perfusion and function with 112 sets of paired data obtained over the first 48 h after birth in 40 preterm infants (24-30 wk of gestation, 510-1900 g at delivery). Echocardiographic measurements of right ventricular output (RVO) and superior vena caval (SVC) flow were performed serially. BP recordings were obtained from invasive monitoring or oscillometry. Modified cotside EEGs were analyzed for quantitative amplitude and continuity measurements. RVO 12 h after birth was related to both EEG amplitude at 12 and 24 h and continuity at 24 h. Mean systemic arterial pressure (MAP) at 12 and 24 h was related to continuity at 12 and 24 h after birth. Multiple regression analyses revealed that RVO at 12 h was related to median EEG amplitude at 24 h and diastolic BP at 24 h was related to simultaneous EEG continuity. In addition, at 12 h, infants in the lowest quartile for RVO measurements (<282 mL/kg/min) had lower EEG amplitude and those in the lowest quartile for MAP measurements (<31 mm Hg) had lower EEG continuity. These results suggest a relationship between indirect measurements of cerebral perfusion and cerebral function soon after birth in preterm infants.
Related Concept Videos
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...