Related Experiment Video
Updated: Aug 9, 2026

Intranasal Administration of CNS Therapeutics to Awake Mice
Published on: April 8, 2013
Increased net water loss by oral compared to nasal expiration in healthy subjects
Sophie Svensson1, Anna Carin Olin, Johan Hellgren
1Department of Occupational and Environmental Medicine, Sahlgrenska University Hospital, Göteborg, Sweden.
Aim Of The Study:
To compare the difference in respiratory water loss during expiration through the nose and through the mouth, in healthy subjects.
Methods:
The study included 19 healthy, non-smoking volunteers without any present history of non-infectious rhinitis, presenting with symptoms of rhinitis, asthma or previous nasal surgery. Nasal and oral expiratory breath condensates were collected using a breath condenser during tidal respiration at indoor resting conditions. During the nasal breath condensate sampling, the subjects were breathing into a transparent face mask covering the nose and the mouth with the mouth closed. During the oral breath condensate sampling, the subjects inhaled through the nose and exhaled through a mouthpiece connected to the condenser. The airflow during the sampling was assessed with a dry-spirometer connected to the condenser. Sampling was stopped after 100 litres of expired air for each breathing mode. Nasal sampling was done before and after decongestion of the nasal mucosa with oxymetazoline, 0.5 mg/ml. The effect on the nasal mucosa was assessed with acoustic rhinometry.
Results:
The mean loss of expired water was 42% less by nasal expiration before decongestion than by oral expiration (1.9 x 10(-3) g/L min compared to 2.7 x 10(-3) g/L min, p < 0.001). The mean expiratory minute ventilation was 9.0 L/min by nasal respiration and 9.8 L/min by oral respiration. Decongestion of the nasal mucosa showed a mean increase of the cross-sectional area at 4 cm from the nostril (1.44 to 1.67 cm2, p = 0.0024), but there was no effect on the net water loss (1.9 x 10(-3) g/Lmin vs 1.9 x 10(-3) g/Lmin).
Conclusion:
This study showed that the net water loss increased by 42% when the breathing mode was switched from nasal to oral expiration during tidal breathing in healthy subjects. Increased water and energy loss by oral breathing could be a contributing factor to the symptoms seen in patients suffering from nasal obstruction.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Suctioning the Nasopharyngeal Airway
Equipment Required
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Nose and Nasal Cavity
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Adaptations that Reduce Water Loss
